DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
BReP-SNAP-T-58 | Error in Vendor Provided Calibration for Pre-Clinical Orthovoltage Irradiator Identified Through Independent Output Check D Carlton1*, T Howard2, Q Chen1, (1) University of Kentuky, Lexington, KY, (2) Texas Oncology, Dallas, TX |
MO-EF-TRACK 3-3 | Investigation of a Simple Calorimeter Design for the Dosimetry of Ultra-High Pulse Dose Rate (FLASH) Electron Beams M McEwen1, A Bourgouin2*, A Schueller3, (1) National Research Council, Ottawa, ON, CA, (2) Carleton University, Ottawa, (3) Physikalisch-Technische Bundesanstalt, Braunschweig |
PO-GeP-I-113 | Evaluation of Dual-Energy CT Reconstructed Virtual Monoenergetic Images for Radiation Therapy Treatment Planning B Broekhoven*, W Godwin, D McDonald, Medical University of South Carolina, Charleston, SC |
PO-GeP-M-18 | A Machine Learning Based Fully Automatic Magnification Calculation Method for Hip DR Photography Y Jia1*, H Wang1, X Jin2, H Du1, W Chen1, B Yang2, (1) Shaanxi Key Laboratory of Network Data Intelligent Processing; UCLA School of Medicine, Xi'an, Shaanxi, CN, (2) Xian Honghui Hospital |
PO-GeP-T-17 | A Custom-Made Jig for In-Air Ionization Chamber Measurements and Quality Assurance of the Mark I-68 Cs-137 Irradiator S Jayarathna*, R Tailor, H Moktan, S H Cho, The University of Texas MD Anderson Cancer Center, Houston, TX |
PO-GeP-T-40 | A Novel Absolute Radiation Dosimetry Approach Measuring Reactive Oxygen Species J Rahimian*, M Hitchler, Kaiser Permanente Los Angeles Medical Center, Los Angeles, CA |
PO-GeP-T-92 | An Adaptive Method for Recalibrating Gafchromic EBT3 Film L Chang*, I-Shou University, Kaohsiung, KHQTW, |
PO-GeP-T-237 | Comprehensive Calibration and Evaluation of a Cone-Beam CT On a Pre-Clinical Small Animal Radiation Research Platform Y Huang1*, Y Zhong1, C Wang1, Y Gonzalez1, C Shen1, X Jia1, (1) The University of Texas Southwestern Medical Ctr, Dallas, TX |
PO-GeP-T-238 | Comprehensive Evaluation and Implementation of Two Independent Methods for Beam Monitor Calibration for Proton Scanning Beam J Shen*, X Ding, Y Hu, Y Kang, W Liu, W Deng, M Bues, Mayo Clinic Arizona, Phoenix, AZ |
PO-GeP-T-269 | Determination of Absorbed Dose to Water Using Fricke Dosimetry for 6 MV Photons Beams C Salata1,2*, V Guimaraes2, A Mantuano2, A Pickler2, C Mota2, M Santos3, C de Almeida2, (1) brazilian nuclear energy authority, Rio De Janeiro, ,BR (2) Radiology Science Laboratory of Rio de Janeiro State University (LCR/UERJ), Rio De Janeiro, ,BR, (3) Instituto Nacional do Cancer, Rio De Janeiro, RJ, BR |
PO-GeP-T-290 | Development of a Water Calorimeter with Plane-Parallel Glass Vessel for Absolute Measurement of Absorbed Dose to Water z wang1,2, S Jin1, K Wang1, J Zhang1*, (1) National Institute of Metrology, Beijing, CN, (2) School of Mechanical, Electronic and Control engineering, Beijing Jiaotong University, Beijing, CN, |
PO-GeP-T-294 | Development of An Automated Routine for Finding the Precise Location of Scintillators Elements and Their Emission Spectrum in a Multi-Point Scintillation Detector B Lessard1,2*, F Larose1,2, F Berthiaume1,2,3, S Lambert-girard1,2,3, F Therriault-Proulx3, L Archambault1,2, (1) Departement de physique, genie physique et optique, et Centre de recherche sur le cancer, Universite Laval, Quebec, CA, (2) CHU de Quebec - Universite Laval et CRCHU de Quebec, Quebec, CA, (3) Medscint inc., Quebec, CA |
PO-GeP-T-437 | Experimental Study for the Absorbed-Dose to Water of Heavy Ion Beam by An Ionization Method S Jin, K Wang*, J Zhang, z wang, National Institute of Metrology, Beijing, Beijing,CN, |
PO-GeP-T-558 | Lead Foil for Flattening Filter Free Reference Dosimetry: Do We Really Need It? D Campos1*, (1) Allegheny Health Network, Pittsburgh, PA |
PO-GeP-T-588 | Monte Carlo and Water Calorimetric Determination of Ionization Chamber Correction Factors for Medium Energy X-Ray Beams J Bancheri1*, S Ketelhut2, L Bueermann2, J Seuntjens1, (1) Medical Physics Unit, McGill University, Montreal, QC, CA, (2) Physikalisch-technische Bundesanstalt (PTB), Braunschweig, Niedersachsen, DE |
PO-GeP-T-611 | Optical Calibration of Radiochromic Film Thickness With IR Dye R Kaiyum1*, N Allam2, C Schruder1, O Mermut1, A Rink1,3, (1) Department of Physics and Astronamy, York Univeristy, Toronto, ON, CA, (2) Department Of Medical Biophysics, University Of Toronto, ON , CA, (3) The Princess Margaret Cancer Centre, University Health Network, Toronto, ON, CA |
SU-B-TRACK 2-7 | Application of Theranostic Gadolinium Based Nanoparticles Loaded in Next Generation Radiotherapy Biomaterials for Magnetic Resonance-Image-Guided Radiotherapy R Mueller1,2,3*, M Moreau3,4,5, S Yasmin-Karim3,4, O Tillement6, R Berbeco3,4, J Hesser1,2,7,8, W Ngwa3,4,5, (1) Department Data Analysis and Modeling in Medicine, Mannheim Institute for Intelligent Systems in Medicine (MIISM), Heidelberg University, 69117 Heidelberg, Germany (2) Heidelberg University, 69117 Heidelberg, Germany (3) Brigham and Women's Hospital, Dana-Farber Cancer Institute, Boston, MA 02115, USA (4) Harvard Medical School, Boston, MA 02115, USA (5) University of Massachusetts Lowell, Lowell, MA 01854, USA (6) Institut Lumière Matière, UMR5306, Université Lyon1-CNRS, Université de Lyon, Villeurbanne, France (7) Interdisciplinary Center for Scientific Computing (IWR), Heidelberg University, 69120 Heidelberg, Germany (8) Central Institute for Computer Engineering (ZITI), Heidelberg University, 68159 Mannheim, Germany |