DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
BReP-SNAP-M-87 | Imaging Dose in Breast Radiotherapy by X-Ray CT Calibration of Cherenkov Light R Hachadorian1*, P Bruza1, M Jermyn1,2, D Gladstone1,3, L Jarvis3, B Pogue1,2,3, (1) Dartmouth College, Hanover, NH, (2) DoseOptics LLC, Lebanon, NH, AF, (3) Dartmouth-Hitchcock Med. Ctr., Lebanon, NH |
BReP-SNAP-T-18 | A Three-Dimensional Electronic Detector Array for Dose Verification in Radiotherapy: Proof of Product D Roa1, R Challco2*, Z Arqque3, O Paucar4, C GUZMAN CALCINA5, A Gonzales6, A Gonzales Galvez7, M Montoya8, J Hernandez-Bello9, (1) University Of California, Irvine, Orange, CA, (2) Universidad Nacional de Ingenieria, Lima, ,PE, (3) Universidad San Antonio Abad, Cuzco, ,PE, (4) Universidad Nacional de Ingenieria, Lima, ,PE, (5) Universidad Nacional Federico Villarreal, Lima, ,PE, (6) Universidad Nacional de Ingenieria, Lima, ,PE, (7) Aliada Contra El Cancer, Lima, ,PE, (8) Universidad Nacional de Ingenieria, Lima, ,PE, (9) HRS Oncology International, Las Vegas, NV |
BReP-SNAP-T-51 | Dosimetry for Advanced Radiotherapy Approaches Using Particle Beams with Ultra-High Pulse Dose Rates in the EMPIR UHDpulse Project A Subiel1*, M McManus2, F Romano3, H Palmans4, A Lourenco5, N Lee6, R Thomas7, F Wilfrid8, G Antonio9, A Mascia10, S Joseph11, E Lee12, A Schueller13, (1) National Physical Laboratory, Teddington, GB, (2) National Physical Laboratory, Teddington, GB, (3) National Physical Laboratory, Teddington, GB,(4) National Physical Laboratory, Teddington, GB,(5) National Physical Laboratory, Teddington, GB, (6) National Physical Laboratory, Teddington,GB, (7) National Physical Laboratory, Teddington,GB, (8) CERN, (9) CERN,(10) University of Cincinnati Medical Center, Cincinnati, OH, (11) University of Cincinnati Medical Center, Cincinnati, OH, (12) University of Cincinnati Medical Center, Cincinnati, OH (13) PTB, Braunschweig, GER |
BReP-SNAP-T-147 | Determination of the Recombination Correction Factor for a Parallel-Plate Chamber Irradiated by Synchrotron-Based FLASH Proton Beams M Yang1*, X Wang1, M Chen2, U Titt1, S Tootake3, T Katayose3, Y Li1, X Zhang1, F Poenisch1, M Umezawa3, S Frank1, A Koong1, X Zhu1, (1) UT MD Anderson Cancer Center, Houston, TX, (2) Ruijin Hospital, Huangpu, Shanghai, CN, (3) Hitachi, Tokyo, Japan. |
MO-CD-TRACK 1-8 | Development of a Quasi-Adiabatic Miniature Graphite Calorimeter for Absolute Clinical Dosimetry of High-Energy Photon Beams F Keszti*1, B Cote1, J Bancheri1, A Sarfehnia2, J Seuntjens1, J Renaud1,3, (1) McGill University, Montreal, QC, CA, (2) Sunnybrook Health Sciences Centre, Toronto, ON, CA, (3) National Research Council Canada, Ottawa, ON, CA |
MO-EF-TRACK 3-3 | Investigation of a Simple Calorimeter Design for the Dosimetry of Ultra-High Pulse Dose Rate (FLASH) Electron Beams M McEwen1, A Bourgouin2*, A Schueller3, (1) National Research Council, Ottawa, ON, CA, (2) Carleton University, Ottawa, (3) Physikalisch-Technische Bundesanstalt, Braunschweig |
PO-GeP-I-1 | 3D Dose Reconstruction Using An In-House Radioluminescence Imaging System M jia*, L Wang, Y Yang, L Xing, X Li, Stanford University, Stanford, CA |
PO-GeP-I-93 | Dose Comparison of Elekta Infinity 4D Symmetry Scan Versus Cone Beam CT I Koistinen1*, M Koistinen2, (1) University of Maine, Orono, ME, (2) CHEM Center for Rad Oncology, Millis, MA |
PO-GeP-P-29 | Quality Control of Knowledge Assessment Questions for Training Courses Held On the IAEA/AAPM TRS-483 Small Field Dosimetry Code of Practice for Dosimetry G Loreti, M Khandekar, K Christaki, D van der Merwe*, Iaea |
PO-GeP-T-38 | A New HVL-Free Method to Calibrate Surface Electronic Brachytherapy Devices Using Depth-Dose Ratios C Valdes-Cortez*1,2, Y Niatsetski3, F Ballester2,4, J Vijande2,4, C Candela-juan5, J Perez-Calatayud4,6, (1) Centro Oncologico del Norte, Antofagasta, Chile. (2) Departamento de Fisica Atomica, Molecular y Nuclear, Universitat de Valencia (UV), Valencia, Spain. (3) R&D Elekta Brachytherapy, Veenendaal, The Netherlands. (4) IRIMED Joint Research Unit (IIS La Fe - UV), Valencia, Spain. (5) Centro Nacional de Dosimetria, Instituto Nacional de Gestion Sanitaria, Valencia, Spain. (6) Radiotherapy Department, La Fe Hospital, Valencia, Spain. |
PO-GeP-T-40 | A Novel Absolute Radiation Dosimetry Approach Measuring Reactive Oxygen Species J Rahimian*, M Hitchler, Kaiser Permanente Los Angeles Medical Center, Los Angeles, CA |
PO-GeP-T-109 | Angular Dependency of the Measurements of the Novel SRS MapCheck Device in the Magnetic Field O Pen*, A Price, Washington University in St. Louis, St. Louis, MO |
PO-GeP-T-120 | Assessing the Accuracy of Ion Chamber Air Kerma Measurements in Synchrotron Produced Monochromatic X-Ray Beams I El Gamal1,2*, B Muir2, M McEwen2, (1) Carleton University, Ottawa, ON, CA, (2) National Research Council, Ottawa, ON, |
PO-GeP-T-238 | Comprehensive Evaluation and Implementation of Two Independent Methods for Beam Monitor Calibration for Proton Scanning Beam J Shen*, X Ding, Y Hu, Y Kang, W Liu, W Deng, M Bues, Mayo Clinic Arizona, Phoenix, AZ |
PO-GeP-T-287 | Development of a Known-Volume Spherical Ionization Chamber E King*, L DeWerd, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison |
PO-GeP-T-290 | Development of a Water Calorimeter with Plane-Parallel Glass Vessel for Absolute Measurement of Absorbed Dose to Water z wang1,2, S Jin1, K Wang1, J Zhang1*, (1) National Institute of Metrology, Beijing, CN, (2) School of Mechanical, Electronic and Control engineering, Beijing Jiaotong University, Beijing, CN, |
PO-GeP-T-309 | Dose Calculation Accuracy Comparison of BrainLab Monte Carlo and Eclipse Acuros XB for SRS/SBRT Planning J Yoon*, A Gray, The University of Rochester Cancer Cen, Rochester, NY |
PO-GeP-T-541 | Investigation of Radiophotoluminescent Glass Dosimeter Response for a Spot Scanning Proton Beam Dosimetry J Nagata*, K Yasui, N Hayashi, S Ogawa, K Ouchi, Graduate school of Health Sciences, Fujita Health University, Toyoake, AichiJP, |
PO-GeP-T-558 | Lead Foil for Flattening Filter Free Reference Dosimetry: Do We Really Need It? D Campos1*, (1) Allegheny Health Network, Pittsburgh, PA |
PO-GeP-T-580 | Mixed Electron-Photon Radiation Therapy Delivery and Quality Assurance VJ Heng1*, M Renaud2, M Serban3, J Seuntjens1, (1) McGill University, Montreal, QC, CA, (2) Polytechnique Montreal, Montreal, QC, CA, (3) McGill University Health Centre, Montreal, QC, CA |
PO-GeP-T-615 | Optimization and Construction of a Glass Vessel and MR-Compatible Water Calorimeter for Use in Clinical Photon and Electron Beams M D'souza1*, H Nusrat2,3, V Iakovenko2,3, J Renaud3, A Sarfehnia1,2,3, (1) Department of Physics, Ryerson Univeristy, Toronto, ON, CA, (2) Department of Medical Physics, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, CA, (3) Department of Radiation Oncology, University of Toronto, Toronto, ON, CA, (4) National Research Council Canada, Ottawa, ON, CA |
SU-F-TRACK 3-7 | Verification of the Output Calibration of MR-Linac Beams Using Reference Alanine Dosimeters M McEwen1*, V Malkov2, B Muir3, A Sarfehnia4, (1) National Research Council, Ottawa, ON, CA, (2) University Health Network, Toronto, ON, CA, (3) National Research Council, Ottawa, ON, (4) Sunnybrook Health Sciences Centre, Odette Cancer Centre, Department of Medical Physics, Toronto, ON, CA |
TH-A-TRACK 5-2 | Dosimetry of Ultra-Short High Dose-Per-Pulse Very High Energy Electron Beams M McManus1, 2*, F Romano3, 1, N Lee1, F Wilfrid4, 6, G Antonio4, Gary Royle2, H Palmans5, 1, A Subiel1, (1) National Physical Laboratory, London, GB ,, (2) University College London, London, GB ,,(3) Istituto Nazionale di Fisica Nucleare, Sezione di Catania, Catania, IT ,,(4) Cern, Geneva, CH ,, (5) MedAustron, Wiener Neustadt, AT ,, (6) CEA-Saclay, IRFU, FR |