|
| | PO-BPC-Exhibit Hall-1 |
|
| Saturday | Improvements in MR Quality Assurance Workflow and Outcomes with a Web-Based Quality Control Database |
| | X.Yang*, K.Little, X.Jiang, D.Hintenlang |
| | PO-BPC-Exhibit Hall-2 |
|
| Saturday | Four-Dimensional Digital Tomosynthesis Based On Visual Respiratory Guidance |
| | D.Kim, S.Kim, T.Suh* |
| | PO-BPC-Exhibit Hall-3 |
|
| Saturday | Is Measurement of CTDIvol with a Helical Scan An Acceptable Alternative to the Standard Single-Slice Methodology? |
| | S.Leon*, R.Kobistek, I.Barreto, B.Schwarz, Z.Zhang, E.Olguin |
| | PO-BPC-Exhibit Hall-4 |
|
| Saturday | Surface Imaging Accuracy for Stereotactic Radiosurgery Setup and Treatment Delivery |
| | J.McCulloch*, V.Bry, D.Saenz, P.Myers, N.Kirby, K.Rasmussen |
| | PO-BPC-Exhibit Hall-5 |
|
| Saturday | Characterization of Siemens FORCE CT Bowtie Filters |
| | J.Salazar*, K.Lewis |
| | PO-BPC-Exhibit Hall-6 |
|
| Saturday | Use of a Conditional Generative Adversarial Network to Synthesize MR of the Prostate |
| | J.Kielbasa*, A.Kubli, R.Mathews, T.Willoughby, O.Zeidan, A.Shah, P.Kelly, S.Meeks |
| | PO-BPC-Exhibit Hall-7 |
|
| Saturday | A Team-Centered Approach to Implementing New Technologies in a Multi-Institutional Cancer Center Setting |
| | C.Abing* |
| | PO-BPC-Exhibit Hall-8 |
|
| Saturday | Correlation of Dosimetric Parameters with Clinical Outcomes in the Treatment of Unresectable Hepatic Metastases with Yttrium-90 Microspheres |
| | W.Wei, V.Sehgal, M.Al-Ghazi* |
| | PO-BPC-Exhibit Hall-9 |
|
| Saturday | Patient-Specific QA On Halcyon 2.0 |
| | E.Laugeman*, A.Heermann, J.Hilliard, M.Roberson, M.Watts, R.Morris, S.Goddu, I.Zoberi, H.Kim, S.Mutic, G.Hugo, B.Cai |
| | PO-BPC-Exhibit Hall-10 |
|
| Saturday | Evaluation of a Dense Planar Diode Array for True Composite SRS Measurements |
| | S.Ahmed*, G.Zhang, E.Moros, V.Feygelman |
| | PO-BPC-Exhibit Hall-11 |
|
| Saturday | Automated Verification Plan Preparation and 2D-3D Gamma Analysis for Proton Patient-Specific Quality Assurance |
| | D.Hernandez Morales*, J.Shan, W.Liu, K.Augustine, M.Bues, M.Davis, M.Fatyga, J.Johnson, D.Mundy, J.Shen, J.Younkin, J.Stoker |
| | PO-BPC-Exhibit Hall-12 |
|
| Saturday | Associations Between Dose-Volume, Quality of Life and Clinical Toxicity Correlations After Lung SBRT |
| | S.Devpura*, I.Chetty, S.Brown, S.Rusu, E.Mayyas, R.Araj, J.Kim, J.Liu, C.Liu, Z.Sun, D.Snell, S.Vance, M.Ajlouni, S.Siddiqui, B.Movsas |
| | PO-BPC-Exhibit Hall-13 |
|
| Saturday | Predicting Individual Target V12Gy for Single Isocenter Multi-Target (SIMT) Stereotactic Radiosurgery(SRS): A Comparison of Three Empirical Methods |
| | T.Li*, H.Zhang, W.Shi, H.Liu |
| | PO-BPC-Exhibit Hall-14 |
|
| Saturday | Efficiency and Accuracy Improvements for Patient Plan Quality Assurance with a Passive Scattering Proton Therapy System |
| | B.Tonner*, C.Curley, G.Georgiev, D.Murff, P.Marvin, R.Tokarz |
| | PO-BPC-Exhibit Hall-15 |
|
| Saturday | MRIdian Linac Daily QA |
| | P.Yadav*, K.Mittauer, K.Vredevoogd, J.Bayouth |
| | PO-BPC-Exhibit Hall-16 |
|
| Saturday | Evaluation of Backscatter Factors (Bw) and Percentage Depth Dose (Pdd) Data in TG-61 Protocol and BJR Supplement 25 for Superficial X-Ray Radiotherapy |
| | C.Chan*, M.Lee |
| | PO-BPC-Exhibit Hall-17 |
|
| Saturday | A Method for Measuring the Setup Accuracy of An IGRT System for Single-Isocentre, Multiple Target SRS Deliveries |
| | E.Gete*, K.Luchka, A.Mestrovic, B.Gill |
| | PO-BPC-Exhibit Hall-18 |
|
| Saturday | Statistical Evaluation of the Isocenter Dose Measurement Option for ArcCHECK CavityPlug Based Patient Specific IMRT/VMAT QA |
| | T.Ren*, J.Bourland |
| | PO-BPC-Exhibit Hall-19 |
|
| Saturday | Dosimetric Impact of Diaphragm Motion and Dynamic MLC Interplay in Lower Thoracic Spine Radiosurgery Using VMAT Technique |
| | B.Zhao*, N.Wen, I.Chetty, K.Snyder, Z.Sun, S.Siddiqui, Y.Huang |
| | PO-BPC-Exhibit Hall-20 |
|
| Saturday | Electron Treatment Plan Comparisons Between 3D-Electron and Monte Carlo Dose Calculations |
| | R.George*, P.Myers, D.Saenz, K.Rasmussen, N.Kirby, S.Stathakis |
| | PO-BPC-Exhibit Hall-21 |
|
| Saturday | Ideal Planning Assistant Application for Guidance in Radiation Treatment Planning |
| | C.Kabat*, H.Parenica, N.Papanikolaou, S.Stathakis |
| | PO-BPC-Exhibit Hall-22 |
|
| Saturday | Characterization of Optically Stimulated Luminescent Dosimeters in a Simulated Fluoroscopy Beam |
| | N.Quails*, C.Schaeffer, A.Heshmat, N.Correa, C.Olguin, I.Barreto, M.Arreola, L.Rill |
| | PO-BPC-Exhibit Hall-23 |
|
| Saturday | Using Modulated and Reflected Light to Correct Clinical Cherenkov Images for Patient-Specific Tissue Variations During Whole Breast Radiotherapy |
| | R.Hachadorian*, P.Bruza, L.Jarvis, D.Gladstone, B.Pogue |
| | PO-BPC-Exhibit Hall-24 |
|
| Saturday | Pre- and Post-ESD in Clinicopathologic Analysis in Early Gastric Cancer |
| | Y.Gao* |
| | PO-BPC-Exhibit Hall-25 |
|
| Saturday | Commissioning a 2.5 MV Portal Imaging Beam in the Eclipse Treatment Planning System |
| | W.Ferris*, W.Culberson, Z.Labby |
| | PO-BPC-Exhibit Hall-27 |
|
| Saturday | Improve the Dosimetric Outcome in Bilateral Head and Neck Cancer (HNC) Treatment Using Spot-ScanningProton Arc (SPArc) Therapy: A Feasibility Study |
| | G.Liu*, A.Qin, X.Li, D.Yan, C.Stevens, P.Kabolizadeh, X.Ding |
| | PO-BPC-Exhibit Hall-28 |
|
| Saturday | Geometric and Dosimetric Differences Due to Image Registration Workflows for Frameless GammaKnife Icon Patients |
| | E.Hubley*, K.Mooney, W.Shi, Y.Yu, H.Liu |
| | PO-BPC-Exhibit Hall-29 |
|
| Saturday | Robustness Evaluation of a Neural Network-Based Photon Beam Profile Deconvolution Method |
| | K.Mund*, G.Yan |
| | PO-BPC-Exhibit Hall-30 |
|
| Saturday | Dosimetric Comparison of Biologically-Guided Radiotherapy and X-Ray-Guided Stereotactic Ablative Radiotherapy for Oligometastatic Prostate Cancer |
| | W.Hrinivich*, R.Phillips, A.Da Silva, N.Radwan, M.Gorin, S.Rowe, K.Pienta, M.Pomper, J.Wong, P.Tran, K.Wang |
| | PO-BPC-Exhibit Hall-31 |
|
| Saturday | Increase in Superficial Dose in Whole-Breast Irradiation with Halcyon Linac Compared to Traditional C-Arm Linacs: In-Vivo Dosimetry and Planning Study |
| | F.O'Grady*, A.Barsky, S.Anamalayil, C.Kennedy, L.Dong, J.Metz, N.Taunk, T.Li |
| | PO-BPC-Exhibit Hall-32 |
|
| Saturday | Measurement of Output Factors with Various Detectors in the Presence of the ViewRay MRIdian Magnetic Field |
| | B.Barraclough*, D.Dunkerley, K.Vredevoogd, B.Paliwal, K.Mittauer, P.Yadav |
| | PO-BPC-Exhibit Hall-33 |
|
| Saturday | An Open-Source Tool to Visualize Potential Cone Collisions While Planning SRS Cases |
| | A.Licon*, A.Alexandrian, N.Kirby |
| | PO-BPC-Exhibit Hall-34 |
|
| Saturday | Comparison of Collapsed Cone Convolution Superposition and Monte Carlo Dose Calculations for Spine SBRT Dose |
| | H.Parenica*, D.Saenz, N.Papanikolaou, S.Stathakis |
| | PO-BPC-Exhibit Hall-35 |
|
| Saturday | A Comparison Between Traditional and Continuous Delivery Methodologies for the Gamma Knife Perfexion |
| | S.Blake*, D.Cheek |
| | PO-BPC-Exhibit Hall-36 |
|
| Saturday | Development of a Stand-Alone Comprehensive Collision Prediction System for Non-Coplanar Radiotherapy |
| | N.Islam*, J.Kilian-Meneghin, M.Podgorsak |
| | PO-BPC-Exhibit Hall-37 |
|
| Saturday | SRS Spine Treatment Planning Study On a Magnetic Resonance Image Guided Linear Accelerator |
| | J.Dolan*, J.Kim, K.Snyder, I.Chetty, N.Wen |
| | PO-BPC-Exhibit Hall-38 |
|
| Saturday | A Simplified Total Body Irradiation Scatter Dose Calculation |
| | N.Astorga*, M.Naessig, S.Stathakis, D.Saenz, K.Rasmussen, P.Myers, N.Papanikolaou, N.Kirby |
| | PO-BPC-Exhibit Hall-39 |
|
| Saturday | Implementation of Risk-Based Plan Evaluation and NTCP Estimation From Intermediate Dose Levels |
| | C.Velten*, P.Brodin, W.Bodner, S.Kalnicki, C.Guha, M.Garg, W.Tome |
| | PO-BPC-Exhibit Hall-40 |
|
| Saturday | Dosimetric Impact Associated with the New 25-Source GammaPodTM Design |
| | P.Sabouri*, Y.Niu, C.Yu, M.Guerrero, E.Nichols, B.Yi, S.Becker |
| | PO-BPC-Exhibit Hall-41 |
|
| Saturday | CyberKnife-Based SBRT for High Intermediate and High Risk Prostate Cancer |
| | K.Lambson*, K.Huang |
| | PO-BPC-Exhibit Hall-42 |
|
| Saturday | Planning and Delivery Performance of the Halcyonâ„¢ Platform for Multiple Small Targets with a Single Isocenter |
| | P.Irmen*, H.Liu, W.Shi, M.Alonso-Basanta, J.Zou, B.Teo, J.Metz, L.Dong, T.Li |
| | PO-BPC-Exhibit Hall-43 |
|
| Saturday | Impact of the MLC Leaf-Tip Model: TPS Dose Calculation Deficiencies and IROC-H Phantom Failures |
| | B.Koger*, R.Price, D.Wang, D.Toomeh, S.Geneser, E.Ford |
| | PO-BPC-Exhibit Hall-44 |
|
| Saturday | An Efficient Automatic Dose-Space Registration Technique for Clinical IMRT/VMAT Quality Assurance with Radiochromic Film Dosimetry |
| | T.Ren*, J.Bourland |
| | PO-BPC-Exhibit Hall-45 |
|
| Saturday | Can the Student Outperform Its Master? A Comparison of Two Automated Inverse Planning Engines Using a Quantitative Quality Plan Metric |
| | A.Smith*, A.Granatowicz, C.Stoltenberg, S.Wang, X.Liang, S.Zhou, C.Enke, A.Wahl, D.Zheng |
| | PO-BPC-Exhibit Hall-46 |
|
| Saturday | Outcome Analysis in Stereotactic Body Radiation Therapy for Spine Metastases: Dose-Response for Toxicity and Pain Relief |
| | B.Ziemer*, M.Susko, S.Braunstein, L.Ma |
| | PO-BPC-Exhibit Hall-47 |
|
| Saturday | Failure Modes and Effects Analysis for Gamma Knife Icon Frameless SRS/FSRT |
| | R.Jakubovic*, A.Goenka, G.Gill, J.Chang |
| | PO-BPC-Exhibit Hall-48 |
|
| Saturday | Characterizing the Response of a Conical, Scintillation-Based Detector for Machine and Patient-Specific Quality Assurance Applications in Photon Radiotherapy |
| | L.Johnson*, M.Price, B.Nelson, A.Yock |